K5.6 standard response horizontal sidewall sprinkler

Pipe Steel Industries offers K5.6 standard response horizontal sidewall sprinkler as part of our fire sprinklers and accessories sourcing range. Use the technical options below to prepare your project enquiry.

Selection details: standards: UL 199, NFPA 13.

Confirm the exact model, dimensions, working conditions and required approvals with our sales team before ordering. Model-specific certificates and availability are verified with the quotation.

Request a Quotation for K5.6 standard response horizontal sidewall sprinklerEmail a product-specific RFQ
K5.6 standard response horizontal sidewall sprinkler — Pipe Steel Industries product catalogue
Representative product photograph. Confirm the model, dimensions and configuration with your quotation.

Technical Specifications

PropertyDetails
StandardUL 199, NFPA 13
FeatureK5.6 (K80), SR, HSW
W. pressure250 / 175 psi
T. pressure500 psi, factory hydrostatic test
O. pressureMin 7 psi
SurfaceRough brass / chrome plated / white painted, etc.

Sizes & Technical Data

Reference options for product selection. Confirm the exact dimensions, model and project approvals with your quotation.

K5.6 standard response horizontal sidewall sprinkler technical table 1
TypeTemperature ratingWorking pressure (psi)Ref. No.
Horizontal sidewall135°F (57°C)250S0401 (UL/FM)
Horizontal sidewall155°F (68°C)250S0402 (UL/FM)
Horizontal sidewall175°F (79°C)250S0403 (UL/FM)
Horizontal sidewall200°F (93°C)250S0404 (UL/FM)
Horizontal sidewall286°F (141°C)250S0405 (UL/FM)
Horizontal sidewall360°F (182°C)250S0406 (UL)
Recessed horizontal sidewall135°F (57°C)250S0407 (UL/FM)
Recessed horizontal sidewall155°F (68°C)250S0408 (UL/FM)
Recessed horizontal sidewall175°F (79°C)250S0409 (UL/FM)
Recessed horizontal sidewall200°F (93°C)250S0410 (UL/FM)
K5.6 standard response horizontal sidewall sprinkler technical table 2
TypeTemperature ratingWorking pressure (psi)Ref. No.
Horizontal sidewall135°F (57°C)175S0421 (UL/FM)
Horizontal sidewall155°F (68°C)175S0422 (UL/FM)
Horizontal sidewall175°F (79°C)175S0423 (UL/FM)
Horizontal sidewall200°F (93°C)175S0424 (UL/FM)
Horizontal sidewall286°F (141°C)175S0425 (UL/FM)

Applications

  • Standard Coverage Fire Sprinklers procurement
  • Fire Sprinklers and Accessories project packages

Finishes & Options

  • Specify size, connection, material and quantity in your enquiry.
  • Request model-specific documentation and destination-port delivery terms.

Get Pricing for K5.6 standard response horizontal sidewall sprinkler

Share your standard, grade, sizes, schedule and quantities — we reply with availability, pricing and a delivery schedule.