Metal-clad (MC) cable

Pipe Steel Industries offers Metal-clad (MC) cable as part of our fire-rated cable and conduit sourcing range. Use the technical options below to prepare your project enquiry.

Selection details: standards: UL 83, UL 1569, NPFA 70.

Confirm the exact model, dimensions, working conditions and required approvals with our sales team before ordering. Model-specific certificates and availability are verified with the quotation.

Request a Quotation for Metal-clad (MC) cableEmail a product-specific RFQ
Metal-clad (MC) cable — Pipe Steel Industries product catalogue
Representative product photograph. Confirm the model, dimensions and configuration with your quotation.

Technical Specifications

PropertyDetails
StandardUL 83, UL 1569, NPFA 70
Temperature90°C dry only for THHN, 90°C wet or dry for THWN-2
Voltage600 V
ComplianceVW-1 vertical wire flame test, FT4/IEEE 1202 vertical tray flame test
ApplicationIndoor / outdoor commercial and Industrial wiring

Sizes & Technical Data

Reference options for product selection. Confirm the exact dimensions, model and project approvals with your quotation.

Metal-clad (MC) cable technical table 1
ConductorGroundingApprox. OD / mmMax DCR / 20°C, Ω/kmRef. No.
14 AWG x 2C, solid14 AWG x 111.68.5C0701 (UL)
14 AWG x 3C, solid14 AWG x 112.38.5C0702 (UL)
14 AWG x 4C, solid14 AWG x 113.18.5C0703 (UL)
12 AWG x 2C, solid12 AWG x 111.95.3C0704 (UL)
12 AWG x 3C, solid12 AWG x 112.75.3C0705 (UL)
12 AWG x 4C, solid12 AWG x 113.65.3C0706 (UL)
10 AWG x 2C, solid10 AWG x 113.63.3C0707 (UL)
10 AWG x 3C, solid10 AWG x 114.73.3C0708 (UL)
10 AWG x 4C, solid10 AWG x 115.83.3C0709 (UL)
Metal-clad (MC) cable technical table 2
ConductorGroundingApprox. OD / mmMax DCR / 20°C, Ω/kmRef. No.
8 AWG x 2C, stranded10 AWG x 117.12.1C0721 (UL)
8 AWG x 3C, stranded10 AWG x 117.92.1C0722 (UL)
8 AWG x 4C, stranded10 AWG x 119.12.1C0723 (UL)
6 AWG x 2C, stranded10 AWG x 118.91.4C0724 (UL)
6 AWG x 3C, stranded10 AWG x 119.91.4C0725 (UL)
6 AWG x 4C, stranded10 AWG x 121.91.4C0726 (UL)
4 AWG x 2C, stranded8 AWG x 124.30.9C0727 (UL)
4 AWG x 3C, stranded8 AWG x 127.50.9C0728 (UL)
4 AWG x 4C, stranded8 AWG x 128.90.9C0729 (UL)

Applications

  • Fire-rated cable and conduit procurement
  • Fire-rated cable and conduit project packages

Finishes & Options

  • Specify size, connection, material and quantity in your enquiry.
  • Request model-specific documentation and destination-port delivery terms.

Get Pricing for Metal-clad (MC) cable

Share your standard, grade, sizes, schedule and quantities — we reply with availability, pricing and a delivery schedule.