Unshielded fire alarm cable (FPLR & FPL)

Pipe Steel Industries offers Unshielded fire alarm cable (FPLR & FPL) as part of our fire-rated cable and conduit sourcing range. Use the technical options below to prepare your project enquiry.

Selection details: standards: UL 1424 / NEC Article 760.

Confirm the exact model, dimensions, working conditions and required approvals with our sales team before ordering. Model-specific certificates and availability are verified with the quotation.

Request a Quotation for Unshielded fire alarm cable (FPLR & FPL)Email a product-specific RFQ
Unshielded fire alarm cable (FPLR & FPL) — Pipe Steel Industries product catalogue
Representative product photograph. Confirm the model, dimensions and configuration with your quotation.

Technical Specifications

PropertyDetails
StandardUL 1424 / NEC Article 760
Temperature-20°C to 75°C
Voltage300 V
ComplianceFPLR/CMR/CL3R, flame test UL 1666 FPL/CM/CMG/CL3, flame test UL 1685 or CSA FT4/IEEE 1202
ApplicationRiser fire alarm wiring, general purpose fire alarm wiring

Sizes & Technical Data

Reference options for product selection. Confirm the exact dimensions, model and project approvals with your quotation.

Unshielded fire alarm cable (FPLR & FPL) technical table 1
SizeConductor typeConductor dia. (mm)Conductor sect. (mm2)Max DCR at 20°C, Ω/kmRef. No.
22 AWG x 4CSolid0.64 x 4C0.3259.1C0201
18 AWG x 2CSolid1.02 x 2C0.8221.4C0202
18 AWG x 4CSolid1.02 x 4C0.8221.4C0203
16 AWG x 2CSolid1.29 x 2C1.3113.5C0204
16 AWG x 4CSolid1.29 x 4C1.3113.5C0205
14 AWG x 2CSolid1.63 x 2C2.088.45C0206
12 AWG x 2CSolid2.05 x 2C3.315.31C0207
Unshielded fire alarm cable (FPLR & FPL) technical table 2
SizeConductor typeConductor dia. (mm)Conductor sect. (mm2)Max DCR at 20°C, Ω/kmRef. No.
22 AWG x 4C7 stranded0.73 x 4C0.32, min55.4C0211
18 AWG x 2C7 stranded1.16 x 2C0.81, min21.9C0212
18 AWG x 4C7 stranded1.16 x 4C0.81, min21.9C0213
16 AWG x 2C7 stranded1.46 x 2C1.28, min13.7C0214
16 AWG x 4C7 stranded1.46 x 4C1.28, min13.7C0215
14 AWG x 2C7 stranded1.85 x 2C2.04, min8.60C0216
12 AWG x 2C7 stranded2.32 x 2C3.26, min5.41C0217

Applications

  • Fire alarm cable procurement
  • Fire-rated cable and conduit project packages

Finishes & Options

  • Specify size, connection, material and quantity in your enquiry.
  • Request model-specific documentation and destination-port delivery terms.

Get Pricing for Unshielded fire alarm cable (FPLR & FPL)

Share your standard, grade, sizes, schedule and quantities — we reply with availability, pricing and a delivery schedule.